home *** CD-ROM | disk | FTP | other *** search
/ Network Support Library / RoseWare - Network Support Library.iso / windows / fyirpt.txt < prev    next >
Text File  |  1992-02-27  |  6KB  |  140 lines

  1.  
  2. (Note: The origin of this information may be internal or external to Novell. 
  3. Novell makes every effort within its means to verify this information. 
  4. However, the information provided in this document is FOR YOUR INFORMATION
  5. only.  Novell makes no explicit or implied claims to the validity of this
  6. information.)
  7.  
  8.           TITLE:     Installing Windows And RPRINTER On Same workstation.
  9.    DOCUMENT ID#:     FYI.P.5272
  10.            DATE:     07JAN92
  11.         PRODUCT:     NetWare
  12. PRODUCT VERSION:     All versions
  13.      SUPERSEDES:     NA
  14.  
  15.         SYMPTOM:     NA
  16.  
  17. ISSUE/PROBLEM
  18.  
  19.      The following are suggestions for installing Windows and Rprinter on the
  20. same workstations:
  21.  
  22.      *     SETUP /I.
  23.  
  24.      Undocumented switch that ignores checking the hardware at the time of
  25. installing Windows.  It needs to be mentioned that leaving the /i out can
  26. also be helpful in some cases.
  27.  
  28.      *     PUT WINDOWS ON A LOCAL DRIVE.
  29.  
  30.      Windows is faster on a local drive than from a Network drive.  Also
  31. sometimes you can work in real mode from the Network but not in enhanced
  32. mode.
  33.  
  34.      *     USE HIMEM.SYS FOR THE MEMORY MANAGER.
  35.  
  36.      Windows has been successfully installed with Qemm386.sys and Emm386.sys
  37. from Quarterdeck and DR DOS 6.0 respectively with Windows on local and
  38. Network drives, however, tweaking these two memory managers can be a
  39. struggle.
  40.  
  41.      *     MAY NEED TO USE HIMEM.SYS /M:1 IN THE CONFIG.SYS.
  42.  
  43.      In the Readme.txt in the Windows subdirectory, it explains the use of
  44. this switch.  It is used to make sure Windows sees a 100% IBM compatible
  45. BIOS.  
  46.  
  47.      Other options include:
  48.   
  49.           1  at               ; IBM AT or 100% compatible.
  50.           2  ps2              ; IBM PS/2
  51.           3  ptlcascade       ; Phoenix Cascade BIOS
  52.           4  hpvectra         ; HP Vectra (A & A+)
  53.           5  att6300plus      ; AT&T 6300 Plus
  54.           6  acer1100         ; Acer 1100
  55.           7  toshiba          ; Toshiba 1600 & 1200XE
  56.           8  wyse             ; Wyse 12.5 Mhz 286 
  57.  
  58.      If HIMEM does not work properly, trying a different method may be
  59. successful.   Specify the switch for your computer type on the
  60. device=HIMEM.SYS line in your CONFIG.SYS file. Computer type corresponds to
  61. either the number or the name of your computer from the table.
  62.  
  63.      For example the following lines are equivalent:
  64.  
  65.           device=c:\himem.sys /M:ps2
  66.           device=c:\himem.sys /M:2
  67.  
  68.      *     GET THE LATEST NETX FROM DOSUP4.ZIP.
  69.  
  70.      Always get the latest Shells found in NOVLIB lib 05. 
  71.  
  72.      *     GET THE NOVELL WORKSTATION UTILITIES FOR WINDOWS FOUND IN
  73. WINUP4.ZIP.   
  74.      These utilities simplify the printing/capture environment in Windows.
  75. They are also found in NOVLIB lib 05.  At the time of installing the
  76. utilities, some changes are made to the system.ini of that workstation. 
  77. These changes include drivers such as VPICDA.386 which can help interrupt
  78. conflicts associated with IRQ's 2 and 9.
  79.  
  80.      *     TRY TO EXCLUDE DIFFICULT ADDRESSES SUCH AS VIDEO RAM AND NIC I/O
  81. WITHIN THE SYSTEM.INI FILE.   
  82.  
  83.      This is documented on page 549 of the Windows User Guide.  The following
  84. is an example:
  85.  
  86.           1.     Find the [386en] section of the System.ini file using a text
  87. editor.
  88.  
  89.           2.     Add the line: EMMExclude=A000-DFFF (or address of problem
  90. areas).
  91.  
  92.           3.     Save the file and reenter Windows.
  93.  
  94.      *     MAY NEED TO AVOID IRQ'S 2, 9, OR 3 WHEN INSTALLING THE NIC IN THE
  95. WORKSTATION.   
  96.  
  97.      IRQ 3 may be a problem if there is a com3 in the workstation and
  98. sometimes  experience interrupt problems even if com3 is not enabled.
  99.  
  100.      *     ALWAYS EXECUTE RPRINTER.EXE BEFORE GOING INTO WINDOWS.   
  101.  
  102.      The syntax from the dos prompt is: rprinter print_server_name
  103. printer_number
  104.  
  105.      *     PUT SPX ABORT TIMEOUT=1000 IN THE SHELL.CFG FILE FOUND ON THE
  106. WORKSTATION.  This often helps when the printer loses connection as seen at
  107. the Print Server's status screen.
  108.  
  109.      *     I/O CONFLICTS WITH THE NIC'S CAN CAUSE PROBLEMS.
  110.  
  111.      On an AST 386sx workstation using an NE2000 set at base I/O of 360 would
  112. run fine with Rprinter and Windows in enhance mode until the job was printed
  113. to the queue serviced by the Rprinter.  At that time the workstation would
  114. hang and the status at the Print Server status screen would show Rprinter not
  115. connected.  If we used IRQ 3 and 5 at I/O address of 300 or 340 it worked
  116. fine all the time.
  117.  
  118.      *     AVOID OTHER TSR'S AT THE WORKSTATION USING BOTH RPRINTER AND
  119. WINDOWS.
  120.  
  121.      *     WINDOWS REQUIRES 2 MEG OF EXTENDED RAM TO RUN IN ENHANCED MODE.
  122.  
  123.      *     WINDOWS REQUIRES THE HMA TO RUN IN ENHANCED MODE.
  124.  
  125.      This means that the 64K byte segment above the one meg boundary (address
  126. FFFFF) has to be unused.  Some applications such as our XMSNETX.COM loads
  127. into the HMA (Hi Memory Area).  Some memory managers such as EMM386.sys from
  128. DRI, load the DR DOS 6.0 kernel into this same HMA, once again not allowing
  129. Windows to run in enhanced mode.  MSDOS 5.0 kernel can have the same effect.
  130.  
  131.      *     There are so many combinations regarding hardware, memory manager
  132. settings, and how users load programs into upper memory, it is more or less
  133. a trial and error situation when using windows and rprinter. There is not a
  134. sure method of installing windows and rprinter on the same workstation and
  135. making them work successfully all the time.
  136.  
  137. From: Kristin Vane And Kimo Lewis